Show simple item record

dc.contributor.authorWalquist, R. L.en_US
dc.date.accessioned2009-05-08T05:17:55Z
dc.date.available2009-05-08T05:17:55Z
dc.date.issued1953-05-07en_US
dc.identifierMC665_r05_M-1913-1.pdfen_US
dc.identifier.urihttp://hdl.handle.net/1721.3/39265
dc.description.abstractThe North Truro CPS-6B is to operate with a scan time of 12 seconds in the 1953 Cape Cod System. The major computing frame for the data processing program will also be set at 12 seconds. A redistribution of ES has been made in order to simplify some of the track-while-scan (TWS) operations and in certain cases to allow a larger number of registers for excessively long sub-programs. The values of stored velocity for the tracks have been changed to correspond to a scan time of 12 seconds.en_US
dc.language.isoenen_US
dc.publisherMIT Digital Computer Laboratoryen_US
dc.relation.ispartofseriesMIT DIC 6889en_US
dc.relation.ispartofseriesProject Whirlwind Memo M-1913-1en_US
dc.relation.ispartofseriesProject Whirlwind Collection, MC665en_US
dc.titleChanges in Internal Storage and Computing Time Allocation Given in M-1913 (Supplement to M-1815: 1953 Cape Cod System)en_US