dc.contributor.authorMorrison, Channingen_US
dc.date.accessioned2009-05-04T21:28:51Z
dc.date.available2009-05-04T21:28:51Z
dc.date.issued1952-10-16en_US
dc.identifierMC665_r04_E-491.pdfen_US
dc.identifier.urihttp://hdl.handle.net/1721.3/38914
dc.description.abstractThe hysteresis loops were obtained in a temperature range from -196 degrees Centigrade to +305 degrees Centigrade. The Curie point of MF-1118 was reached at approximately 305 degrees Centigrade, and the maximum Squareness Ratio occurred at approximately 30 degrees Centigrade. The flux density and the coercivity were both a maximum at -196 degrees Centigrade and both decreased with increasing temperature.en_US
dc.language.isoenen_US
dc.publisherMIT Digital Computer Laboratoryen_US
dc.relation.ispartofseriesMIT DIC 6889en_US
dc.relation.ispartofseriesProject Whirlwind Engineering Note E-491en_US
dc.relation.ispartofseriesProject Whirlwind Collection, MC665en_US
dc.titleHysteresis Loop Characteristics of MF-1118 for Different Temperaturesen_US