Show simple item record

dc.contributor.authorWatt, C. W.en_US
dc.date.accessioned2009-06-15T20:32:38Z
dc.date.available2009-06-15T20:32:38Z
dc.date.issued1956-03-28en_US
dc.identifierMC665_r16_M-4270en_US
dc.identifier.urihttp://hdl.handle.net/1721.3/40646
dc.descriptionIncludes: general; output system tests; auxiliary drum system tests; system operating during December, January, and February; and figures.en_US
dc.description.abstractThe reliability of the XD-1 system has in general improved since the last report was issued (Memo 6M-4100 covering November, 1955). Overall reliability - up from 89% in December to 95% in February. Mean-good time between failures: No appreciable change. Lowest - 3.0 hours/biweekly period. Highest - 4.9 hours/biweekly period. Assigned time: Increased almost to the 168 hour per week limit during January, February and March. The tape drives are giving excessive trouble; these are being studied actively by both MIT and IBM to try to determine the cause. During January the Output System and the Auxiliary Drum System were successfully acceptance tested.en_US
dc.language.isoenen_US
dc.publisherLincoln Laboratory - Division 6en_US
dc.relation.ispartofseriesDivision 6 Memo M-4270en_US
dc.relation.ispartofseriesProject Whirlwind Collection, MC665en_US
dc.subject.otherreliability studiesen_US
dc.subject.otherfailuresen_US
dc.subject.otherinterruptionsen_US
dc.subject.otheroperational timeen_US
dc.subject.othercomponent reliabilityen_US
dc.subject.otherXD-1en_US
dc.titleXD-1 system operation and results of system tests from 3 December 1955 through 10 March 1956en_US